Very usefull to clean fuels recipitation of paraffin and asphalt or with lubricating oils mixing of different types of oil can form solid encrustations on the mesh. It is heavy duty emulsifying liquid , which is Extremely and effectively removes tenacious carbon deposits, burnt grease, Oily residues and lacquers , from fuel oil and lube oil purifiers, filters, separators. Effective cleaning of fine meshes is achieved by soaking in RXSOL-16-1665-025 followed by blasting with compressed air using a cleaning gun.
Mechanical cleaning (scrubbing and brushing ) damages the filter which results in poor performance.
Cleaning process and requirement of time depends on the type of the contamination. With fuels recipitation of paraffin and asphalt or with lubricating oils mixing of different types of oil can form solid encrustations on the mesh.
RXSOL-16-1665-025 can be undercooled or overheated during storage but remains fully usable when returned to normal temperature.
MESH CONTAMINATED WITH HEAVY OIL:
Elements contaminated with heavy oil must be soaked in a standard commercial aromatic solvent. After soaking the elements are cleaned by high pressure Cleaning Device using RXSOL-16-1665-025 solution.
May be used directly or diluted in the ratio of 1 part concentrate to 5 parts water, ( or 1 . Ratio of any solvent like diesel )
Manual Cleaning of the Candle Filter Elements
NOTE ::: Drained the automatic filter by automatic back-flushing (i.e. all filter chambers).
1 Then soak the filter element assembly, with the openings of the candle elements facing down in a suitable tank filled with RXSOL-16-1665-025 solvent.
2 The soaking time is completely depends on cleaning method :
a)In cold RXSOL-16-1665-025 cleaner the maximum soaking time is 24 hours.
b)In hot solution the maximum soaking time is 12 hours.
3. After soaking remove the whole filter element assembly from the tank and for dry to keep all parts on place it on a suitable perforated sheet metal.
4. Then you may blow compressed air through the candles from the inside to the outside.
5. After this procedure the complete filter element assembly should be immersed in fresh cleaner, with the candle element opening down-wards, and rinsed through with an up and down motion.
6 Allow the filter element assembly to drain again and dry it by blowing compressed air through it again from the inside to the outside. The manual cleaning procedure described here has produced adequate results (ca. 60 % clean) in similar applications.
Note : CLEANING of filter can be enhance with high pressure machine.
INSTRUCTIONS FOR USE:
Use of RXSOL-16-1665-025 is not restricted to a particular method of cleaning. Depending on the operating conditions, RXSOL-16-1665-025 can be used in a dip bath, in a spraying plant, in steam jetting or in manual application using a cloth, brush or sponge. It can be used warm or cold. RXSOL-16-1665-025 is miscible with water - even seawater.
Concentration for mesh cleaning: 1 : 2,5
Temperature: up to a maximum of 60 °C
The concentration depends on the type and thickness of the adhesive substance to be removed. When used in concentration below 1 : 30 rinsing is usually not required. No visible film remains on the surface